Esterase from Bacillus subtilis E9

Enzyme Description

Extremophile
No
EC Number

Sequence

Length: 166 amino acids
ASYNFFAIKNYLVSQGWQSNKLYAIDFYDKTGNNLNNGPQLASYVDRVLKETGAKKVDIVAHSMGGANTLYYIKYLGGGNKIQNVVTLGGANGLVSSKALPGTDPNQKILYTSIYSLNDEIVINSLSRLQGARNIQLYGIGHIGLLSNSLVNGYIKEGLNGGGLNT
P. Soumya et al. (2022) β€” An Esterase with Increased Acetone Tolerance from Bacillus subtilis E9 over Expressed in E. coli BL21 Using pTac Bs-est Vector
Molecular Biotechnology  Β· doi:10.1007/s12033-022-00458-4 β†—  Β· Activity - Classical
9 measurements
Database ID
β€”
Sequence Annotation
Explicit - Provided
Protein Source
Recombinant, host bacterium Escherichia coli BL21 (DE3)

Experimental Data (9 measurements)

9 measurements
Property Assay Solvent Solvent Volume Aqueous Reference Measured Value Units Extraction method Data type Solution pH Temperature Substrate(s) Product(s) Cofactor(s) Shaking Comments
Activity - Classical Activity measured by absorbance spectrophotometry (p-nitrophenol absorbance measurement) in the presence of organic solvent n-Hexane 30 % v/v 100 84 % Direct Continuous 100 mM Tris-HCl buffer 8 Room temperature 1 mM p-Nitrophenol acetate Acetic Acid , p-Nitrophenol β€” β€” Classical aqueous control (in %) | Uncertainty about temperature
Activity - Classical Activity measured by absorbance spectrophotometry (p-nitrophenol absorbance measurement) in the presence of organic solvent Dimethyl Sulfoxide (DMSO) 30 % v/v 100 93 % Direct Continuous 100 mM Tris-HCl buffer 8 Room temperature 1 mM p-Nitrophenol acetate Acetic Acid , p-Nitrophenol β€” β€” Classical aqueous control (in %) | Uncertainty about temperature
Activity - Classical Activity measured by absorbance spectrophotometry (p-nitrophenol absorbance measurement) in the presence of organic solvent Acetone 30 % v/v 100 96 % Direct Continuous 100 mM Tris-HCl buffer 8 Room temperature 1 mM p-Nitrophenol acetate Acetic Acid , p-Nitrophenol β€” β€” Classical aqueous control (in %) | Uncertainty about temperature
Activity - Classical Activity measured by absorbance spectrophotometry (p-nitrophenol absorbance measurement) in the presence of organic solvent Ethanol 30 % v/v 100 80 % Direct Continuous 100 mM Tris-HCl buffer 8 Room temperature 1 mM p-Nitrophenol acetate Acetic Acid , p-Nitrophenol β€” β€” Classical aqueous control (in %) | Uncertainty about temperature
Activity - Classical Activity measured by absorbance spectrophotometry (p-nitrophenol absorbance measurement) in the presence of organic solvent Methanol 30 % v/v 100 67 % Direct Continuous 100 mM Tris-HCl buffer 8 Room temperature 1 mM p-Nitrophenol acetate Acetic Acid , p-Nitrophenol β€” β€” Classical aqueous control (in %) | Uncertainty about temperature
Activity - Classical Activity measured by absorbance spectrophotometry (p-nitrophenol absorbance measurement) in the presence of organic solvent Acetone 30 % v/v 100 95 % Direct Continuous 100 mM Tris-HCl buffer 8 Room temperature 1 mM p-Nitrophenol acetate Acetic Acid , p-Nitrophenol β€” β€” Classical aqueous control (in %) | Uncertainty about temperature
Activity - Classical Activity measured by absorbance spectrophotometry (p-nitrophenol absorbance measurement) in the presence of organic solvent Acetone 50 % v/v 100 94 % Direct Continuous 100 mM Tris-HCl buffer 8 Room temperature 1 mM p-Nitrophenol acetate Acetic Acid , p-Nitrophenol β€” β€” Classical aqueous control (in %) | Uncertainty about temperature
Activity - Classical Activity measured by absorbance spectrophotometry (p-nitrophenol absorbance measurement) in the presence of organic solvent Acetone 70 % v/v 100 96 % Direct Continuous 100 mM Tris-HCl buffer 8 Room temperature 1 mM p-Nitrophenol acetate Acetic Acid , p-Nitrophenol β€” β€” Classical aqueous control (in %) | Uncertainty about temperature
Activity - Classical Activity measured by absorbance spectrophotometry (p-nitrophenol absorbance measurement) in the presence of organic solvent Acetone 90 % v/v 100 96 % Direct Continuous 100 mM Tris-HCl buffer 8 Room temperature 1 mM p-Nitrophenol acetate Acetic Acid , p-Nitrophenol β€” β€” Classical aqueous control (in %) | Uncertainty about temperature

Visualization : Activity β€” Classical

One bar per measurement. Colour = solvent, shade = solvent volume.

Structure

Drag to rotate Β· Scroll to zoom Β· Right-click drag to pan Β· Powered by Mol*